The ROTANTA 460 RC enables efficient and rapid results in research and analytical laboratories. The centrifuge helps to reduce centrifugation times substantially and can be relied on to handle a high throughput of samples. Its powerful refrigeration capability means that the chosen temperature will be reached quickly and maintained.
With the swing-out rotor the maximum RCF is 6,446, and an RCF of 24,400 can be achieved with an angle rotor. The temperature can be set to any desired value in the range -20 °C to +40 °C (-4 °F to +104 °F). The centrifuge is also equipped with stand-by cooling. Its outstanding performance, reliable cooling and comprehensive range of accessories enable laboratory procedures to be carried out quickly and free of interruptions.
Its maximum capacity of three litres per run is valued in clinics and laboratories as well as R&D laboratories in the life sciences. A wide range of accessories is available for high-throughput screening of active substances in research laboratories.
The ROTANTA 460 RC is valued in the fields of biotechnology, molecular biology and throughout the pharmaceutical industry because of its autoclavable and aerosol-tight accessories. The ROTANTA 460 RC has a rotor with a maximum RCF of 6,446 for the centrifugation of filter plates.
The underbench ROTANTA 460 RC is provided with castors. It can be easily pushed under a lab bench and thus frees up space on top of the bench.
Safety and comfort in the workplace using carriers with a single-hand clamp lock
The clamp lock of the 4880 and 4890 carriers can be operated without difficulty with just one hand. The carriers can be comfortably carried by the clamp whether the lid is in place or not since, in contrast to the products from other manufacturers, the clamp is mounted on the carrier and not on the lid. If the lid is in place, the carrier can not only be carried with ease, it is also safe to transport.

- With the clamp in the “open” position the lid can be easily fitted and removed.
- With the clamp in the central position the carrier is sealed to prevent aerosol formation and can be safely carried to the centrifuge, workbench or another working space.
- With the clamp in the “close” position the carrier can be centrifuged without aerosol formation. The absence of aerosols has been verified by the TÜV in accordance with DIN EN 61010, Part 2-020
Advantages
- Fixed angle rotors enable high RCF values:
An RCF of 24,400 with a capacity of 30 x 1.5 / 2.0 ml tubes
An RCF of 18,038 with a capacity of 6 x 94 ml tubes
An RCF of 14,025 with a capacity of 6 x 250 ml tubes
- High capacity with swing-out rotors:
4 x 750 ml with a maximum RCF of 4,779
24 microtitre plates / 4 filter plates with a maximum RCF of 4,211
12 microtitre plates / 2 filter plates with a maximum RCF of 6,446
120blood collection tubes with a maximum RCF of 4,637
- Extensive range of accessories
- The centrifuge is easy to use thanks to its C control panel
- The temperature can be set to any desired value in the range -20 °C to +40 °C (-4 °F to +104 °F)
- Stand-by cooling
- Motor-driven lid locking
Field of Applications
The centrifuge is suitable for centrifugation in
- Clinical chemistry
- Pharmaceutical research
- Biotechnology
- Molecular biology