Operators can work safely and smoothly without approaching their hands to the chamber opening when opening/ closing the lid.
[ Model / Effective capacity ] | |
---|---|
HG-50 | HG-80 |
Automatic lid opening and closing system
The lid can be opened / closed just by pressing the switch. Operators can work safely and smoothly without approaching their hands to the chamber opening when opening / closing the lid.
Electro-mechanical lid lock system II
Inside the body there are several high rigid sliders which interlock in the circumferential direction.
The electro-mechanical lid lock system II employs the automatic slide lock method that can securely lock the lid by engaging the sliders with the guides provided around the lid.
Dual interlock mechanism
The lid is locked by dually detecting the chamber pressure and chamber temperature during operation.
The lock state is maintained even if an operation is manually interrupted.
Lock release temperature setting
The lid lock release temperature can be set for every mode and memory number within the range of 60°C to 97°C.
Forced cooling unit
After sterilization, the chamber pressure is lowered by cooling with a fan to shorten the time to unloading.
Dual detection system for residual air
The residual air which may cause sterilization failure is dually detected to always maintain the appropriate sterilization conditions for loads.
Exhaust level setting
An exhaust level can be selected from four levels.
Fine exhaust can be performed automatically, and fine exhaust adjustment is possible even in exhaust.
Condensation treatment of steam to reduce unpleasant steam emissions
The steam emitted at exhaust is condensed by a water-cooling unit.
The steam containing unpleasant odors, discharged into the room is reduced.
Air removal time setting
The air removal time that is effective for sterilization of Durham tubes etc. can be set.
Notification of drainage bottle status
Full water state of a drainage bottle is automatically detected and the state is notified with lamp and sound.
Memory function
There are 3 memories for each mode and the set contents are registered.
Programmable auto-start function
This is a timer function that starts an operation at the set time.
EU model available
EU Model:Products compliant with european Standards (ENs)
MODE 1: LIQUID | ![]() |
Heating | ![]() |
Sterilization | ![]() |
Variable exhaust | ||
---|---|---|---|---|---|---|---|---|
Main applications: Sterilization of liquid, which can withstand high temperature and high pressure steam such as water, culture medium, reagent, reagent solution, liquid medicine, etc., and sterilization of waste using sterilization bag. | ||||||||
MODE 2: AGAR | ![]() |
Heating | ![]() |
Sterilization | ![]() |
Variable exhaust | ![]() |
Warming |
Main applications: Sterilization of agar medium (It is warmed at constant temperature to prevent clotting after sterilization.) | ||||||||
MODE 3: SOLID | ![]() |
Heating | ![]() |
Sterilization | ![]() |
Forced exhaust | ||
Main applications: Sterilization of instruments made of glass, ceramic, metal or rubber that can withstand high temperature, high pressure steam and rapid pressure reduction during exhaust. | ||||||||
MODE4: DISSOLUTION | ![]() |
Heating | ![]() |
Warming | ||||
Main applications: Dissolution of agar medium (It is warmed at constant temperature to prevent clotting after heating.) |
Recorder | Automatic water supply |
Floating sensor |
---|---|---|
![]() |
![]() |
|
(Image is a chart type recorder.) - Chart type recorder: 6-point dotting - Hybrid recorder: 8-point dotting
|
Manual water supply to the chamber becomes unnecessary. | A sterilization timer operates after the temperature of the materials to be sterilzed reaches the set temperature. |
Stainless steel round wire basket | Stainless steel sterilization bucket (without hole) | Stainless steel sterilization bucket (with holes) | Stainless steel round wire basket with solid bottom |
---|---|---|---|
![]() |
![]() |
![]() |
![]() |
[For HG-50?HG-80] φ338 x H220 mm |
[For HG-50] φ330 x H185 mm [For HG-80] φ330 x H270 mm |
[For HG-50] φ330 x H185 mm [For HG-80] φ330 x H270 mm |
It is recommended to use when using a sterilization bag. A large capacity and bucket-shape bottom can prevent the chamber from being contaminated when a sterilization bag is broken. [For HG-50] φ330 x H430 mm [For HG-80] φ330 x H690 mm
|
Detergent for autoclave | Sterilization bag | Deodorizer |
---|---|---|
![]() |
![]() |
![]() |
Detergent to remove culture media, water scale sticked to the inside of a chamber [Standard amount of use] 1 cap of detergent in 2 L of water (20 ml - 1%)
500 ml |
Special structure reinforced film. Heat resistant temperature is 130°C [Type: A] 200 pcs 500 x 700 mm [Type: B] 200 pcs 620 x 820 mm
|
Deodorizer for the "unpleasant odor" generated during sterilization of culture media etc. It melts smoothly in the sterilization process and exerts a deodorization effect. Standard amount of deodorant according to the autoclave capacity less than 40 L: 2-3 T at once from 40 L to 60 L: 4 T at once from 60 L to 100 L: 6 T at once 100 T / bottle |
Sterilization tape, Sterilization label, Sterilization bag |
---|
![]() |
Ask us for prices and more details. |
Product name | HICLAVE HG series | ||
---|---|---|---|
Model | HG-50 | HG-80 | |
Effective capacity | 50 L | 76 L | |
Chamber size (φ x H mm) | 364 x 482 | 364 x 730 | |
Operation mode | 4 modes (LIQUID, AGAR, SOLID, DISSOL), 3 settings can be stored for each cycle | ||
Temperature setting range |
Sterilization | 105°C - 135°C Variable | 105°C - 135°C Variable |
Dissolution | 60°C - 100°C Variable | ||
Warming | 45°C - 60°C Variable | ||
Lid lock | 60°C - 97°C Variable | LIQUID, AGAR, DISSOL modes: 60°C - 95°C Variable, SOLID mode: 60°C - 97°C Variable |
|
Time setting range |
Sterilization | 1 min - 300 min, Remaining time is displayed | |
Dissolution | 1 min - 60 min, Remaining time is displayed | ||
Warming | 24 h, fixed | ||
Air removal | 5 min - 10 min Variable | 8 min - 16 min Variable | |
Auto-start timer | Program autoclave to start 1 min to 99 h later | ||
Exhaust setting | 4 levels from 0 to 3, Variable, In SOLID mode, it is fixed to level 3 (forced cooling) | ||
Fan cooling | ON / OFF, In SOLID mode, it is set to ON (Forced fan cooling) | ||
Exhaust treatment | Steam condensation by water cooling | ||
Maximum working pressure | 0.26MPa | ||
Thermometer | Digital display 5.0°C - 137.9°C | ||
Pressure gauge | Digital display 0MPa - 0.3MPa / Analog display 0MPa - 0.4MPa | ||
Safety devices | Pressure safety valve, Over - current and earth leakage breaker, Low water cut off device | ||
Alarms, error display | Low water heating, Temperature sensor wire disconnection, Over-temperature, Over-cool, Over-pressure, Lid abnormality, Exhaust valve abnormality, Heater abnormality, etc. |
||
Outside dimensions (W x D x H mm) | 455 x 691 x 890 | 455 x 691 x 1030 | |
Weight (Approximately) | 62 kg | 73 kg | |
Pressure vessel category | Small sized pressure vessel | ||
Chamber material | Stainless steel (SUS304) | ||
Power supply | AC110V / 120V / 220V / 230V / 240V, 50Hz / 60Hz (Specify the voltage when ordering.) |
AC220V / 230V / 240V, 50Hz / 60Hz (Specify the voltage when ordering.) |
|
Required power supply facility | 3kW (2kW for AC110V / 120V / 220V / 230V / 240V) | 3.8kW | |
Power connection | Ring terminal |
||
Supplied accessories | Wire mesh basket (2 for HG-50, 3 for HG-80), Bottom plate, Drainage bottle, Caster stopper (2) |
Specifications | Kindly refer to the "Overview" tab. |