Overview
Features
1. Lock mechanism
It minimizes the lever shifting and avoids drifting of volume setting during pipetting.
2. Ejector
One-hand ejection enables to minimize fatigue and provide better operation.
3. Glass-made counter window
This will not be worn out within the clean bench work.
4. Body 1
Material used has high tolerance to solvents and to drop impact.
It is fully autoclavable as well.
5. Body 2
Reduced the weight up to 30% of that of the conventional Nichiryo products.
6. Nozzle
Nozzle design for easy tip fitting.
Reduced the weight up to 30%
- Reduced fatigue for pipetting compared with the conventional products * in-house comparison
Easy maintenance
- New function provides the maintenance easily * in-house comparison
Reduced ejector load
- Improved operability by one-hand ejection remarkably * in-house comparison
Strong material for UV resistance
- This will not be worn out within the clean bench work
- Suitable for culture work in clean bench
Fully autovlavable [121°C for 20minutes ]
- Easy sterilization process
Lock mechanism for volume setting
- It minimizes the lever shifting and avoids drifting of volume setting during pipetting.
Durable body
- Material used has high tolerance to solvents and to drop impact.
4 sizes [V, S, L, K] covering wide volume range from 0.5 to 300µL
Revolving handle [360?] to fixate convenient position in pipetting
- Suitable for dispensing to 96 well micro plates
Specifications
| Cat. No | Channel | Volume Setting | Volume range(μL) | Increments(μL) | Usable tips |
|---|---|---|---|---|---|
| 00-NPM-8V | 8 | Digital Setting | 0.5 ~ 10 | 0.01 | BMT2-UT/UTWR, FUT/FUTRB |
| 00-NPM-8S | 5?100 | 0.1 | BMT2-SG/SGR, FSG/FSGRB * | ||
| 00-NPM-8L | 20?200 | 0.2 | BMT2-SG/SGR | ||
| 00-NPM-8K | 30?300 | 1 | BMT2-K/KR | ||
| 00-NPM-12V | 12 | 0.5?10 | 0.01 | BMT2-UT/UTWR, FUT/FUTRB | |
| 00-NPM-12S | 5?100 | 0.1 | BMT2-SG/SGR, FSG/FSGRB * | ||
| 00-NPM-12L | 20?200 | 0.2 | BMT2-SG/SGR | ||
| 00-NPM-12K | 30?300 | 1 | BMT2-K/KR |
* The AC and CV values largely depend on the operator's and the environment under which the pipette is used.
AC & CV
| Cat. No | Volume(μL) | Accuracy(%) | Precision(%) |
|---|---|---|---|
| 00-NPM-8V 00-NPM-12V |
1 | ±8.0 | ≤5.0 |
| 5 | ±4.0 | ≤2.0 | |
| 10 | ±2.0 | ≤1.0 | |
| 00-NPM-8S 00-NPM-12S |
10 | ±3.0 | ≤2.0 |
| 50 | ±1.0 | ≤0.8 | |
| 100 | ±0.8 | ≤0.3 |
| Cat. No | Volume(μL) | Accuracy(%) | Precision(%) |
|---|---|---|---|
| 00-NPM-8L 00-NPM-12L |
20 | ±3.0 | ≤0.6 |
| 100 | ±1.0 | ≤0.4 | |
| 200 | ±0.9 | ≤0.3 | |
| 00-NPM-8K 00-NPM-12K |
30 | ±3.0 | ≤1.0 |
| 150 | ±1.0 | ≤0.5 | |
| 300 | ±0.6 | ≤0.3 |
- * The AC and CV values largely depend on the operator's skill and the environment under which the pipette is used.
Stands

| Cat. No | Storing capacity |
|---|---|
| 00-MLT-STD2 (ABS) | 6pcs * For only Multi-Channel, 3pcs is maximum storing capacity. |
Tray

| Cat. No | Q'ty |
|---|---|
| 00-88-TY | 50 |